13.8V 25Amp linear power supply
Þessi síða hefur verið heimsótt
sinnum síðan 7. Júní 2003
- This is my 13.8V 25Amp power-supply. With over-current (26 Amps) and over-voltage
(16 Volts) protection.
- Uses fold-back current limiting.
- Short circuit current is
around 8 Amps.
- Uses 3 (or 4, which is better) IRF150n power MOSFETs as pass transistors. LM723
can drive the MOSFETs directly.
- Needs big heat-sink, 1.2 C/W for the FETS and bridge rectifier, or
forced air cooling.
- Yes, the MOSFETs need equalizing resistors (0.1 Ohm 5 Watt) if they
are not closely matched. Short circuit current of 8 Amp must be
divided between the 3 MOSFETs, as the total power dissipated
is 160 Watts. Better is to use 4 MOSFETS's to lessen the stress during
short circuit.
- Power supply schematic, pdf(12k))
Circuit details
I got the transformer from an old heater controller. Any transformer can be
used, it has to provide about 19V RMS at the rated current. Extra transformer
may be needed for the 30V supply for LM723 regulator.
The bridge rectifier is a 35Amp type and the 40.000uF capacitor is
computer grade, I used 3 12.900uF 40V surplus caps.
The LM723 regulator is used to control the 3 or 4 MOSFETs, I used MOSFETs
instead of bipolar transistors as the MOSFETs can be driven directly
by the LM723. The gates of the MOSFETs are protected by 15V zener diodes.
0.1 Ohm resistors are used to equalize the current between the MOSFETs and
also to for current sensing. Fold-back current limiting is done by
R5 and D4 which provide extra current into R14 when the output voltage
is under VREF, and thereby lower the current limit set by the 0.1 Ohm
resistors.
The output voltage is set by R11 and should be set to 13.8V.
3 led indicator are used, one for AC power, one for current limit indication
and one for monitoring the VOUT from LM723.
The crowbar circuit is for over-voltage protection and fires at about 16 Volts.
The voltage is sensed by R31 and R32 and compared to the reference voltage
provided by zener diode Z5 which is 6.8 V.
The 230V MOV is used to suppress any spikes on the 230V AC line.
Two fuses are used, 3.15 Amp Slow for the AC and 20 Amp for the DC.
A 10 Ohm NTC inrush current limiter should be inserted in series
with the 220 V AC input line to limit the turn on surge current.
The P6K839A is a 36V zener voltage suppressor, any 1W 36V zener can be
used instead, it is for protecting the LM723 which has max voltage rating
of 40V.
73 de TF3MA
Schematic diagram drawn using gschem